ELECTRICALC PRO Compliant with 2005, 2002, 1999, 1996 NEC®
Electrical Contractors, Designers, Electricians and Lighting Specialists solve tough electrical calculations in seconds and deliver those solutions in conformance with the latest NEC®. The ElectriCalc® Pro is a complete electrical reference tool that will save time, trouble and money. Update to future code revisions with an easy-to-install kit. Includes Armadillo Gear™ protective Hard Case.
It helps you solve for:
- Wire Sizes
- Integrated Voltage Drop
- Conduit Sizing
- Motor Full-Load Amps
- Fuse and Breaker Sizes
NEC® Table Number displayed when performing Wire Size calculations
- Service and Equipment Grounding Conductor Sizes
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
Parallel Resistance
- Ohm’s Law Calculations – enter any two values to solve for the third
- Circular MILS wire sizes
It helps you:
- Work directly in and convert between Amps, Watts, Volts, Volt-Amps, kVA, kW, PF% and EFF% and DC Resistance
- Calculate wire sizes per NEC® 310-16 and 310-17; Copper or aluminum, 3Ø/1Ø, 60°C, 75°C, 90°C insulation ratings and 100% or 125% of ampacity. Adjust wire sizes for ambient temperatures other than 30◦ C and for more than three wires in a raceway
- Integrated voltage drop solutions. Find minimum VD wire size, maximum Length for any given wire size, drop percentage, actual number and percentage of Volts dropped
- Conduit sizing for 12 types of conduit. Per 2005 NEC® Table C1-C12, find sizing of all common conduits for any combination for #THW, #XHHW and # THHN wires. Plus, gives fill percentages, cross-sectional areas, remaining areas and more
- Find Motor Full-Load Amps per Current NEC®. Works in 1Ø and 3Ø with the new expanded tables for 3Ø induction (to 500 hp) synchronous (to 200 hp) and DC motors per NEC® 430-247, 430- 248 and 430-250.
- Calculates Fuse and Breaker Sizes. Solves fuse and breaker sizes per NEC® 430-52
- Parallel and derated wire sizing
Parallel Resistance
- NEC Table number Displays when performing Wire Sizes calculations
Sizes overload protection per NEC® 430-32
- Automatically finds NEMA starter sizes.
- Calculates service and equipment grounding conductor sizes per NEC® 250-122 and 250-66; plus works directly in electrical terms.
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
- Ohm’s Law Calculations – enter any two values to solve for the third.
- Circular MILS wire sizes
Additional Features:
- Works as Standard Math Calculator with +, -, x, ÷, +/-, %, Π, 1/x, X2, and √.
- Auto Shut-Off extends battery Life, Memory
- Update to future code revisions with easy-to-install kit.
Includes:
- Long-Life Battery
- Easy-to-follow User’s Guide
- Handy Pocket Reference Guide
- Ergonomically designed, Armadillo Gear® 360° flip-top cover protective case
|

click for large
picture |